MICROTEK 100 KVA ONLINE UPS 3 PHASE IN 3 PHASE OUT without isolation transformer
Product Details:
- Power Rating 100KVA
- Product Type online ups
- Frequency (MHz) 50 Hz or 60 Hz Hertz (HZ)
- Protection Core Electrical Protection True Online Double-Conversion continuously converts AC DC AC, isolating load from mains disturbances. Overload Protection shuts down or shifts to bypass if load exceeds rated capacity, protecting UPS and connected equipment. Short Circuit Protection detects and clears short-circuit conditions to prevent damage. Surge Protection input surge suppression ( 6 kVA across each phase to neutral/ground), helpful against voltage spikes and transient surges. EMI/RFI Protection (C-3 Level) limits electrical noise from interference that can disturb sensitive electronics. Voltage & Frequency Safeguards Input Voltage Regulation / Power Conditioning reduces harmful sags, swells, and fluctuations before they reach the load. Active Power Factor Correction (PFC) improves input quality and reduces stress on mains and generator supplies. Frequency Synchronization & Converter Mode maintains stable output frequency even with input frequency shifts. Battery Safety & Backup Protection Battery Deep Discharge Protection prevents over-discharge that can damage batteries. Extendable Charging Design optimized charging stages to improve battery life and safety. Emergency Power Off (EPO) allows safe rapid shutdown during emergencies. Bypass & Continuity Features Static & Maintenance Bypass automatic/manual bypass ensures uninterrupted power during maintenance or UPS faults. Generator Compatibility protects from generator power irregularities when used as a secondary source. Monitoring & Alerts LCD Touch Panel with Alarms displays system status and alerts for fault conditions (e.g., overload, battery low). Multiple Communications (SNMP/USB/RS-232) for remote monitoring/management and automated shutdowns. Why These Protections Matter Prevents Damage from Power Surges & Fluctuations: Sudden spikes, sags, and noise can harm sensitive equipment like servers, PLCs, and telecom gear surge and conditioning protection mitigate that risk. Ensures High Availability: Bypass features and continuous power conversion help maintain uptime even during UPS faults or maintenance. Protects the Battery System: Deep-discharge and controlled charging extend battery life and prevent premature failures. Alarms & Monitoring: Early warnings allow you to take corrective actions before failures occu
- Usage backup
- Size standard
- Warranty 1 year
- Click to View more
MICROTEK 100 KVA ONLINE UPS 3 PHASE IN 3 PHASE OUT without isolation transformer Price And Quantity
- 1 Unit
- 728611.06 INR/Unit
MICROTEK 100 KVA ONLINE UPS 3 PHASE IN 3 PHASE OUT without isolation transformer Product Specifications
- 250 Kilograms (kg)
- black
- 3 Phase In - 3 Phase Out
- Smart 7-inch touch-panel LCD display
- Core Electrical Protection True Online Double-Conversion continuously converts AC DC AC, isolating load from mains disturbances. Overload Protection shuts down or shifts to bypass if load exceeds rated capacity, protecting UPS and connected equipment. Short Circuit Protection detects and clears short-circuit conditions to prevent damage. Surge Protection input surge suppression ( 6 kVA across each phase to neutral/ground), helpful against voltage spikes and transient surges. EMI/RFI Protection (C-3 Level) limits electrical noise from interference that can disturb sensitive electronics. Voltage & Frequency Safeguards Input Voltage Regulation / Power Conditioning reduces harmful sags, swells, and fluctuations before they reach the load. Active Power Factor Correction (PFC) improves input quality and reduces stress on mains and generator supplies. Frequency Synchronization & Converter Mode maintains stable output frequency even with input frequency shifts. Battery Safety & Backup Protection Battery Deep Discharge Protection prevents over-discharge that can damage batteries. Extendable Charging Design optimized charging stages to improve battery life and safety. Emergency Power Off (EPO) allows safe rapid shutdown during emergencies. Bypass & Continuity Features Static & Maintenance Bypass automatic/manual bypass ensures uninterrupted power during maintenance or UPS faults. Generator Compatibility protects from generator power irregularities when used as a secondary source. Monitoring & Alerts LCD Touch Panel with Alarms displays system status and alerts for fault conditions (e.g., overload, battery low). Multiple Communications (SNMP/USB/RS-232) for remote monitoring/management and automated shutdowns. Why These Protections Matter Prevents Damage from Power Surges & Fluctuations: Sudden spikes, sags, and noise can harm sensitive equipment like servers, PLCs, and telecom gear surge and conditioning protection mitigate that risk. Ensures High Availability: Bypass features and continuous power conversion help maintain uptime even during UPS faults or maintenance. Protects the Battery System: Deep-discharge and controlled charging extend battery life and prevent premature failures. Alarms & Monitoring: Early warnings allow you to take corrective actions before failures occu
- steel
- 1 year
- 50 Hz or 60 Hz Hertz (HZ)
- power supply
- 0 C to 40 C Celsius (oC)
- online ups
- backup
- 400 VAC / 415 VAC) Volt (v)
- 50 Hz or 60 Hz Hertz (HZ)
- 97.4 cm 60 cm 160 cm Centimeter (cm)
- standard
- 100KVA
- 305 478 VAC Volt (V)
MICROTEK 100 KVA ONLINE UPS 3 PHASE IN 3 PHASE OUT without isolation transformer Trade Information
- 7 Days
Product Description
Product Description Microtek Make 100KVA 3:3Phase 384480V Supermax+ Series On Line UPS
The Microtek Supermax+ 100 kVA Online UPS is a high-capacity industrial/enterprise-grade UPS designed for critical power backup in commercial, IT, industrial, and data-center environments. It uses true online double-conversion technology (VFI-SS-111) to provide continuous, clean, and stable AC power even during severe mains fluctuations or complete power loss making it suitable for sensitive equipment and heavy electrical loads.
Key Specifications (Typical)
Power & Phase
-
Rated Power: 100 kVA ( 90 kW) output capacity.
-
Input / Output: 3-Phase in 3-Phase out configuration.
-
Output Voltage: Around 400 V 415 V 3.
-
Power Factor: Approximately 0.9 (usable real power).
Electrical Performance
-
Double-Conversion Online Topology: Converts incoming AC to DC and back to AC eliminates transfer delays and protects against sags, surges, and frequency variations.
-
Input Power Factor: 0.99 improves overall efficiency.
-
Output Waveform: Stable pure sine wave ideal for sensitive loads.
-
Total Harmonic Distortion (THD): Low THD (<35%), even with non-linear loads.
-
Zero Transfer Time: Seamless switching from mains to battery.
Batteries & Runtime
-
Battery DC Bus: 384 480 V (external battery bank).
-
Battery Type Compatibility: Supports Lead-Acid, SMF, and Lithium-Ion external batteries.
-
Runtime: Depends on battery size and configuration (user-configurable).
Controls & Communication
-
LCD Control Panel: For status, output, and alarm info.
-
Communication Ports: RS-232 & USB (SNMP optional).
Other Features
-
Active Power Factor Correction (PFC) on input for efficient utility usage.
-
Built-in Static Bypass: Automatic bypass in events of overload or internal faults.
-
Generator Compatible: Works with standby generators (proper sizing recommended).
-
Parallel Capability: Can be paralleled with other units for redundancy or capacity growth.
-
Isolation Transformer: Optional accessory (not included unless specified).
Physical & Operating
-
Typically weighs around 250 kg.
-
Designed for indoor installation in controlled environments (0-40 C).
What Transformer-Less / Without Isolation Transformer Means
This UPS model is normally built without an isolation transformer by default that means it delivers efficient power conversion without a bulky transformer in the main power path. You can optionally add a separate isolation transformer if your site requires galvanic isolation for safety or regulatory reasons, but the standard UPS unit itself doesnt include one helping reduce cost, weight, and footprint.
Ideal Use Cases
Data centers and server farms
Industrial control systems
Manufacturing lines and automation
Telecom sites
Large office backup infrastructure
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+